POWER OVER ETHERNET
PoE Field Guide
A technical installer guide to IEEE PoE types, PSE and PD behaviour, switch power budgets, cabling considerations and fault diagnosis.
Separate three different power questions
PoE troubleshooting becomes much clearer when three limits are kept separate: what the powered device requires, what a specific switch port can provide, and what the switch can provide in total across all powered ports. Passing one of those checks does not automatically pass the other two.
IEEE PoE types
| Common name | IEEE basis | Cisco summary of maximum PSE power |
|---|---|---|
| PoE | 802.3af, Type 1 | 15.4 W |
| PoE+ | 802.3at, Type 2 | 30 W |
| PoE++ | 802.3bt, Type 3 | 60 W |
| 4-pair PoE | 802.3bt, Type 4 | 90 W |
These figures describe the PSE-side classification in Cisco's standards summary. The power available to a powered device can be lower because the cabling itself has loss. For design, verify the actual switch and PD data sheets rather than treating the table as a guarantee for every device.
PSE, PD and negotiation
The Power Sourcing Equipment, usually a switch or injector, detects and classifies a Powered Device before applying standards-based power. Some platforms can also use LLDP or vendor-specific mechanisms to exchange power requirements. A device simply being fitted with an RJ45 socket does not prove it accepts IEEE PoE.
Per-port capability vs total switch budget
A 30 W capable port does not mean a 24-port switch can supply 30 W to all 24 ports at the same time. The switch has a published total PoE budget that must be compared with the sum of allocated or expected device loads. Some switches also change available PoE budget when power-supply options change.
Detailed guide: how to calculate a PoE switch budget.
Cabling matters
PoE current flows through the copper conductors, so resistance creates heat. Bundle size, conductor gauge, ambient temperature and cable construction can affect temperature rise. This is why high-power PoE should be considered during cabling design rather than added as an afterthought. Follow the cable manufacturer's remote-power guidance and the applicable cabling standard for the installation.
Connector workmanship also matters because poor contact can add resistance and local heating. Do not rely only on data continuity when a powered endpoint behaves intermittently.
PoE device will not power up
- Confirm the device is designed for IEEE PoE and identify the required type/class or published input requirement.
- Confirm the selected switch port supports the required standard and is administratively enabled for PoE.
- Check switch PoE status, detected class and fault messages.
- Check whether the switch has enough remaining total PoE budget.
- Confirm the data link uses suitable four-pair cabling and that all required conductors terminate correctly.
- Substitute a known-good patch lead where patch leads are part of the path.
- Test the permanent cabling if the fault follows the cable.
- Only after the power path is proven should you focus on IP configuration or application behaviour.
Detailed guide: PoE device not powering.
PoE device reboots or drops under load
Intermittent power can come from total budget exhaustion, port-level faults, cable/connector resistance, unstable upstream AC/UPS power or a PD whose peak requirement exceeds what the PSE allocates. Compare switch logs and port PoE telemetry with the timing of the reboot. If the event occurs when several devices start simultaneously, check total budget and power-supply limits rather than replacing the network cable immediately.
UPS planning for PoE switches
A PoE switch may supply substantial downstream load in addition to its own electronics. For UPS sizing, use the switch's actual or published input requirement and the intended powered-device load. Do not size a UPS only from the switch's non-PoE base consumption. Runtime should come from verified UPS manufacturer runtime data for the relevant load and model.
Documentation
For important powered endpoints, record switch name, port, device, required PoE mode, observed allocation where available and whether the port is backed by UPS power. This turns a future "camera is offline" problem into a traceable power and network path.
Related resources
PoE Budget Planner | Troubleshooting Centre | PoE switches at Server Warehouse | UPS categories
Technical references
These sources support the standards, test-method and manufacturer-specific statements on this page. Project specifications and current manufacturer documentation take precedence for a real installation.
Go deeper: installation and configuration
Use the procedure-driven playbooks when you need the practical installation, configuration, verification and troubleshooting steps.